DESAIN PERKUATAN ELEMEN BALOK, KOLOM, DAN HUBUNGAN BALOK-KOLOM PADA BANGUNAN GEDUNG PINEWOOD APARTMENT JATINANGOR
Tantyo Gunardhi Indra Prasti (2012) | Tugas Akhir | Teknik Sipil
Bagikan
Ringkasan
Ketika pekerjaan konstruksi bangunan Pinewood Apartemen mencapai 90% dari pekerjaan total, pemilik memutuskan untuk menambah jumlah lantai dari 19 lantai menjadi 21 lantai. Dalam studi ini, Fiber-Reinforced Polymer (FRP) adalah material yang digunakan untuk perkuatan struktur eksisting. Properti material FRP yang digunakan memiliki modulus elastisitas E_f= 230 GPa, tegangan ultimit f_fu^*= 4900 MPa dan regangan ultimite ε_fu^*= 0,021. Desain perkuatan awal, dimulai dengan perkuatan lentur pada balok. Kapasitas momen balok meningkat hingga 49% akibat pemasangan FRP dengan luas penampang A_f= 17 mm². Kapasitas geser balok meningkat hingga 32% akibat pemasangan FRP dengan luas penampang A_f= 34 mm² dan jarak antara FRP untuk perkuatan geser balok s_f= 150 mm. Instalasi FRP dengan tebal t_f= 0,34 mm pada kolom dalam studi ini dapat meningkatkan kapasitas tekan beton hingga 18% karena efek kekangan yang diberikan FRP. Namun peningkatan tersebut akan berubah tergantung pada rasio lebar dan tinggi penampang kolom. Kata Kunci: Perkuatan, Balok, Kolom, Hubungan Balok-Kolom, Fiber-Reinforced Polymer.
Ringkasan Alternatif
When construction work of Pinewood Apartment building reached 90 % of the total work, the owner decided to add the number of the floor from 19 levelss to be 21 levels. In this study, Fiber-Reinforced Polymer (FRP) was the material which was used for structure existing retrofitting. The material properties of FRP which was used have a modulus of elasticity E_f= 230 GPa, ultimate tensile strength f_fu^*= 4900 MPa and ultimate tensile strain ε_fu^*= 0.021. The previous retrofitting design was started by retrofitting the bending of beam. The capacity of beam was increased up to 49% due to the installation of FRP with a broad of cross section of A_f= 17 mm². Shear capacity of beam was increased up to 32% due to the installation of FRP with a cross-sectional area A_f= 34 mm² and distance between FRP to shear retrofitting of beam s_f= 150 mm. Installation of FRP with thick t_f= 0,34 mm that is used on the column in this study could increase capacity of concreteÂ’s pressure up to 18% due to the effect of confinement that given. However, this increase will change depends on the ratio of width and height cross-section of the column. Keywords: Retrofitting, Beam, Column, Beam-Column joint, Fiber-Reinforced Polymer.
Sumber