Kaji Eksperimental Pengaruh Penggunaan Pipa Kapiler dan TXV Terhadap Kinerja Sistem Refrigerasi Cascade
Shovia Sania Zain (2021) | Skripsi | -
Bagikan
Ringkasan
Sistem refrigerasi cascade merupakan gabungan dari dua sistem refrigerasi tunggal, yaitu sistem high stage dan sistem low stage yang bekerja secara terpisah dimana evaporator high stage system menyerap kalor dari kondenser low stage system. Sistem refrigerasi ini menggunakan dua jenis alat ekspansi, yaitu Thermostatic Expansion Valve (TXV) dan pipa kapiler. Pada hal ini, perbandingan performansi dilakukan pada sistem refrigerasi cascade dengan melakukan variasi alat ekspansi TXV dan pipa kapiler pada sistem low stage. Kedua alat ekspansi tersebut memiliki karakteristik dan pengaruh yang berbeda terhadap performansi sistem, oleh karena itu perlu dilakukannya uji performansi untuk mengetahui nilai COP dan efisiensi sistem dari penggunaan masing-masing alat ekspansi. Dari hasil pengukuran dan pengolahan data didapatkan nilai rata-rata COPaktual saat menggunakan TXV sebesar 0,92, nilai COPcarnot rata-rata sebesar 2,19, dan nilai efisiensi sistem sebesar 42%. Sementara itu, untuk sistem yang menggunakan pipa kapiler sebagai alat ekspansi, nilai COPaktual rata-rata sebesar 0,98, nilai COPcarnot rata-rata sebesar 2,25, dan efisiensi sistem 43%. Kata Kunci: Sistem Refrigerasi Cascade, COP, Efisiensi.
Ringkasan Alternatif
The cascade refrigeration system is a combination of two single refrigeration systems, namely the high stage system and the low stage system which work separately where the high stage system evaporator absorbs heat in the low stage system condenser. This refrigeration system uses two types of expansion devices, namely the Thermostatic Expansion Valve (TXV) and the capillary tube. In this case, the performance comparison is carried out in the cascade refrigeration system by varying the TXV expansion device and capillary tube in the low stage system. The two expansion tools have different characteristics and effects on system performance, therefore it is necessary to conduct a performance test to determine the COP value and system efficiency from the use of each expansion device. From the measurement and data processing results, it was obtained that the COP actual value when using TXV was 0.92, the COPcarnot average value was 2.19, and the system efficiency value was 42%. Meanwhile, for systems that use a capillary tube as an expansion device, the average COP value is 0.98, the COPcarnot average is 2.25, and the system efficiency is 43%. Keywords: Cascade Refrigeration System, COP, Efficiency Keywords: Cascade Refrigeration System, COP, System Efficiency.
Sumber
Judul Serupa
  • Kaji Eksperimental Pengaruh Penggunaan Pipa Kapiler dan Thermostatic Expansion Valve (TXV) Terhadap Kinerja Sistem Brine Cooling
  • Kaji Eksperimental Pengaruh Penggunaan TXV dan Pipa Kapiler Terhadap Kinerja Sistem Mini Chiller untuk Aquascape