Perpustakaan judul masih dalam tahap pengembangan, admin siap menampung kritik dan saran
Pengaruh Panjang Pipa Penghubung Indoor Unit & Outdoor Unit Terhadap Kinerja Ac Split Wall-Mounted
Risma Santani (2017) | Tugas Akhir | -
Bagikan
Ringkasan
Jenis alat sistem pengkondisi udara yang banyak digunakan pada berbagai aplikasi hunian dan kenyamanan yaitu jenis AC Split Wall-mounted. Dalam instalasinya, kondisi ruangan menjadi parameter yang harus diperhatikan untuk penempatan indoor unit dan outdoor unit. Panjang pipa penghubung indoor unit dan outdoor unit menentukan volume refrigeran yang berpengaruh terhadap laju alir refrigeran dan tekanan kerja kompresor. Pengaruh tekanan kerja kompresor berdampak terhadap torsi penggerak kompresor yang akan merespon melalui besarnya arus yang dialirkan sebagai daya input kompresor. Metoda pengujian dilakukan berdasarkan pada siklus refrigerasi kompresi uap aktual untuk menentukan kinerja AC Split Wall-mounted. Pengujian dilakukan pada AC Split dengan kapasitas 1 PK dan setting temperatur konstan pada 16oC. Variasi panjang pipa yang digunakan yaitu 5 meter, 4 meter, 3 meter dan 2 meter pada kondisi pengisian refrigeran 420 gram dan volume minimal. Hasil dari baseline yaitu pada panjang 5 meter dan volume 420 gram, AC bekerja pada tekanan kompresor 310,26 kPa dan arus 3,683A serta diperoleh COP 2,69. Pada pengisian volume refrigeran 420 gram, AC dengan panjang pipa 4 meter, 3 meter, dan 2 meter bekerja pada tekanan dan arus kompresor berturut-turut yaitu 430,35 kPa dan 3,722 A; 492,975 kPa dan 3,904 A; 634,318 kPa dan 4,04 A. COP yang dihasilkan berturut-turut yaitu 2,424; 2,245 dan 2,131. COP tertinggi diperoleh pada volume minimal sesuai panjang pipa yaitu dengan panjang pipa 5 meter, 3 meter, dan 2 meter pada volume minimal diperoleh COP berturut-turut yaitu 2,69; 2,70 dan 2,78. Kata Kunci: panjang pipa, outdoor unit, indoor unit, volume refrigeran, COP.
Ringkasan Alternatif
The type of equipment of air conditioning system that is commonly used in various residences and comfort applications are AC Split Wall-mounted. In the installation, the conditions of the room become a parameter that will be choosen by the costumer for placement of the indoor unit and the outdoor unit. The length of the connecting pipe from the indoor unit to outdoor unit determines the volume of refrigerant which affect the refrigerant flow and the pressuring of compressor working. The effect of the pressuring compressor working, has an impact on the compressor driving torque that will respond through the amount of current being discharged as the compressor's input power. The testing method is based on the actual vapor compression refrigeration cycle to determine the performance of Split Wall-mounted AC. The testing was did on AC Split Wall-mounted with capacity of 1 PK and setting the constant temperature at 16o C. Variation of pipe length used is 5 meter, 4 meter, 3 meter and 2 meter at 420 gram refrigerant charging condition and minimum volume. The result of the baseline in the pipe length 5 meter and volume of 420 gram, AC works on the compressor pressure 310,26 kPa, current 3,683 A and retrieved COP 2,69. At 420 gram refrigerant volume filling, AC with the length of pipe 4 meter , 3 meter and 2 meter work on the compressor pressure and current consecutively are 430,35 kPa and 3,722A; 492,975 kPa and 3,904 A; 634,318 kPa and 4,04 A. COP that is obtained consecutively are 2,424; 2,245 and 2,131. The highest COP is obtained at minimum volume based on the pipe length 5 meter, 3 meter and 2 meter with the minimum volume that is obtained by COP consecutively are 2,69; 2,70 and 2,78. Keywords: the length of pipe, outdoor unit, indoor unit, refrigerant volume, COP.