Rancang Bangun Modul Praktikum Proteksi Gangguan Fasa Ke Tanah Menggunakan Rele Terprogram Vamp 40
Arief Fardani (2017) | Tugas Akhir | Teknik Elektro
Bagikan
Ringkasan
Keandalan sistem tenaga listrik dari pembangkitan sampai dengan distribusi sangat diperlukan baik oleh pelanggan maupun pemasok tenaga listrik, Namun keandalan tersebut sulit untuk diwujudkan karena sering terjadinya gangguan-gangguan pada sistem jaringan distribusi listrik. Gangguan tersebut dapat merusak transformato rsebagai akibat dari mengalirnya arus gangguan yang melebihi arus nominalnya. Maka perlu dipasang rele GFR untuk mengamankan gangguan fasa ketanah agar transformator terhindar dari gangguan tersebut. Rele terprogram VAMP 40 mempunyai beberapa karakteristik seperti bnv Normaly Inverse, Very Inverse, Extremelly Inverse dan Long time Inverse yang digunakan didalam Proyek Akhir berupa pembuatan modul praktikum proteksi gangguan fasa ke tanah. Dari hasil pengujian karakteristik waktu-arus dan simulasi gangguan hubung singkat fasa ke tanah maka diperoleh data-data lalu dianalisa, dari hasil analisa menunjukan bahwa rele tersebut masih mempunyai akurasi yang baik untuk sistem proteksi. Kata Kunci: Ground Fault Relay (GFR) , Karakteristik Rele, Vamp 40.
Ringkasan Alternatif
The reliability of electrical power system from the power station until the distribution is very important either for costumers or for the electrical energy supplier. It is hard to realize the reliability, because of the problems in electrical distribution system. The problems is affect the transformator as a result of fault current flow that surpass the nominal current. So that it is necessary to install Ground Fault Relay to protection transformer from phase to ground fault. Programmed relay VAMP 40 that has some kind of current-time characteristic like Normally Inverse, Very Inverse, Extremely Inverse and Long Time Inverse characteristics is using in final project to design and build practical module of earth fault protection. From testing of current-time characteristic and simulation short circuit setting on medium voltage feeder simulator completed with data analyzing indicates that this relay still have good accuracy for protection system. Keywords: Ground Fault Relay (GFR), Relay Characteristic, Vamp 40.
Sumber
Judul Serupa
- Rancang Bangun Modul Praktikum Proteksi terhadap Gangguan Fasa ke Tanah menggunakan Rele GE MIF II
- Rancang Bangun Modul Praktikum Proteksi Rele Arus Lebih menggunakan Rele Terprogram VAMP 40