Ringkasan
Rancang bangun simulator koordinasi proteksi arus lebih menggunakan relai Sepam T20 dan MCGG 82. Simulator ini dibuat karena dalam sistem jaringan distribusi umumnya terdapat lebih dari satu sistem proteksi sehingga setiap proteksi perlu dikoordinasikan agar tidak terjadi tumpang tindih saat terjadi gangguan dan agar apabila terjadi gangguan salah satu proteksi gagal bekerja maka proteksi yang lain harus dapat menggantikan perannya dalam mengisolir gangguan tersebut. Dalam proses pembuatan simulator ini perlu dilakukan perancangan fungsional lalu menentukan cara kerja dari simulator yang akan dibuat. Setelah itu lalu menentukan spesifikasi komponen yang dibutuhkan sesuai dengan perancangan fungsional agar komponen yang dibutuhkan sesuai dengan fungsi yang dibutuhkan pada plant simulator. Lalu dibuat perancangan kontruksi serta peletakan komponen sesuai plant simulator agar peletakan komponen tidak sembarangan dan nantinya akan mempersulit saat dilakukan wiring. Simulator ini nantinya dapat membantu bagaimana cara mempelajari setting untuk koordinasi relai dan dapat menyimulasikan koordinasi relai proteksi terhadap arus lebih akibat gangguan beban lebih atau hubung singkat. Koordinasi pada relai arus lebih atau Over Current Relay (OCR) dapat dilakukan dengan tiga macam cara untuk mengkoordinasi relai yaitu: time grading dengan perbedaan waktu, current grading dengan perbedaan setting arus, time and current grading gabungan dari keduanya. Dimana OCR yang digunakan adalah SEPAM T20 dan MCGG 82. Pembuatan simulator ini belum ada sebelumnya di Laboratorium Sistem Distribusi Tenaga Listrik Politeknik Negeri Bandung. Kata kunci: Gangguan arus lebih, koordinasi relai arus lebih, SEPAM T20, MCGG 82.
Ringkasan Alternatif
Design of a simulator protecting overcurrent coordination overcurrent is using Sepam T20 and MCGG 82 relays. This simulator is required because in operation, the power distribution system will not be rid of a disruption. The most common disruption is the over current , that is caused by internal and external factors. Over current disruption is often caused by the installation of a load more than the nominal current of the distribution equipment. So, it will be caused a damage to the distribution equipment and it should be prevented by the protection device. As not to cause damage. One of the main protections in power grids is the overcurrent relay (OCR). In fact, there is often a failure of operation from one relay when experiencing a current disturbance therefore need another protection relay which helps in overcoming the current disruption. So, if there both of over current coordinated protection relays will work to secure the system parts that occur interference. Coordination over current relay or Over Current Relay (OCR) can be done in three ways to coordinate relays, namely: time grading with time difference, current grading with different current settings, combined time and current grading of both. Where OCR used is SEPAM T20 and MCGG 82. Making of this simulator not yet exist in Laboratory of Power Distribution System of Electricity Polytechnic of Bandung. Keywords: Over current disruption, coordination of over current relay, SEPAM T20, MCGG 82.
Sumber
Judul Serupa
  • Rancang Bangun Simulator Koordinasi Proteksi Arus Lebih Pada Jaringan SUTM Tipe Radial Menggunakan Relai VAMP 40 Dan MCGG 82
  • Rancang Bangun Simulator Koordinasi Proteksi Arus Lebih Pada Jaringan SUTM Tipe RADIAL Menggunakan Relai MIF II Dan MCGG 82
  • Rancang Angun Simulator Koordinasi Proteksi Pada Jaringan SUTM Tipe Radial Menggunakan Relai MICOM P124 Dan MCGG 53
  • Rancang Bangun Simulator Koordinasi Proteksi Arus Lebih Pada Jaringan SUTM Tipe Radial Menggunakan Relai MCGG 53 Dan MK 1000A
  • Rancang Bangun Simulator Koordinasi Proteksi Arus Lebih Pada Jaringan SUTM Tipe Radial Menggunakan Relai Micom P124 Dan MK1000A
  • Rancang Bangun Simulator Koordinasi Proteksi Arus Lebih Pada Jaringan SUTM Tipe Radial Menggunakan Relai SEPAM 1000 Dan MCGG 53
  • Rancang Bangun Simulator Koordinasi Proteksi Arus Lebih Pada Jaringan SUTM Tipe Radial Menggunakan Relai MICOM P122 Dan MCGG 53